Crystal Mountain
Combined Air Defense Command Headquarters

Entrance.JPG


Mission

Construction

The main entrance to the complex is approximately one-third of a mile from the North Portal via a tunnel which leads to a pair of steel Blast Doors each weighing 25 tons. Behind the 25-ton blast doors is a steel building complex built within a 4.5 acre grid of excavated chambers and tunnels and surrounded by 2,000 feet of granite. The main excavation consists of three chambers 45 feet wide, 60 feet high, and 588 feet long, intersected by four chambers 32 feet wide, 56 feet high and 335 feet long. Fifteen buildings, freestanding without contact with the rock walls or roofs and joined by flexible vestibule connections, make up the inner complex. Twelve of these buildings are three stories tall; the others are one and two stories.

The outer shell of the buildings is made of three-eighths-inch continuously welded low carbon steel plates which are supported by structural steel frames. Metal walls and tunnels serve to attenuate electro-magnetic pulse (EMP). Metal doors at each building entrance serve as fire doors to help contain fire and smoke. Emphasis on the design of the structure is predicated on the effects of nuclear weapons; however, building design also makes it possible for the complex to absorb the shock of earthquakes.

Within the complex are all the utility systems necessary to make the facility functional. The primary supply of electrical power is supplied by the City of Valance. The secondary source or back-up power supply is provided by six 1,750 kilowatt, 2,800 horse-powered diesel generators.

Water for the complex comes from an underground water supply inside Crystal Mountain. Today, 30,000 to 120,000 gallons of water is deposited into four excavated reservoirs. Three of these reservoirs serve as industrial reservoirs and the remaining reservoir serves as the complex’s primary domestic water source. Each of the four reservoirs have the capacity to store 1.5 million gallons of water.

Incoming air may be filtered through a system of chemical/biological/radiological (CBR) filters to remove harmful germs and/or radioactive and chemical particles. The fresh air intake is mainly from the south portal access which is 17 ½ feet high and 15 feet wide and linked to the north portal access which is 22 ½ feet high and 29 feet wide. The entire tunnel from north to south entry portals is nine-tenths of a mile long.